Hangzhou Qianrong Automation Equipment Co.,Ltd

Hangzhou Qianrong Automation Equipment Co.,Ltd. focus on ultrasonic application, in good faith to win customers

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Ultrasonic Spray Coating Machine /

Medical Testing Tube Ultrasonic Coated System 60Khz Penetrator Nozzle Nebulizer

Contact Now
Hangzhou Qianrong Automation Equipment Co.,Ltd
Visit Website
City:hangzhou
Province/State:zhejiang
Country/Region:china
Contact Person:MsTina
Contact Now

Medical Testing Tube Ultrasonic Coated System 60Khz Penetrator Nozzle Nebulizer

Ask Latest Price
Video Channel
Brand Name :FUNSONIC
Model Number :FS800
Certification :CE
Place of Origin :CHINA
MOQ :1 UNIT
Price :Negotation
Payment Terms :T/T, Western Union
Supply Ability :1000 unit per month
Packaging Details :Packed by Wooden Case
Production Name :Ultrasonic Precision Spraying Machine
Frequency :60Khz
Max Power :1-15w
Continuous Spraying Volume Max :0.5-10ml/min
Effective Spraying Width :1-m
Spray Uniformity :≥95%
Solution Viscosity :≤15cps
Input Voltage :220V±10%/50-60Hz
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Medical Testing Tube Ultrasonic Coated System 60Khz Penetrator Nozzle Nebulizer


Description:

The vacuum blood collection and ultrasonic spraying technology uses a probe type ultrasonic nozzle to coat the inner wall of the blood collection or injection tube. It mainly has the following applications:
1. Surface coating of blood collection vessels: Ultrasonic probing spray can be used to form a thin film or coating on the surface of vacuum blood collection vessels. This coating can be used to improve the biocompatibility, anticoagulation, or prevent thrombosis of blood collection vessels.
2. Antibacterial coating: Through ultrasonic probing spraying, antibacterial agents or materials with antibacterial properties can be sprayed on the surface of vacuum blood collection vessels. This helps to reduce the risk of bacterial contamination during the blood collection process of blood collection vessels.
3. Vascular markers: Ultrasonic probing spray can be used to spray visible markers, such as fluorescent dyes or other visualization agents, on vacuum blood collection vessels. This helps to make it easier to observe and locate the blood collection vessel during the blood collection process.

Parameters:

Product TypeSyringe Tube Ultrasonic Spray Coating FS800
Spray Nozzle Operating Frequency60KHz (Optional 40Khz)
Nozzle Power1-15W
Continuous Spraying Volume Max0.01-2ml/min
Effective Spraying Width1-m
Spray Uniformity≥95%
Solution Conversion Rate≥95%
Solution Viscosity≤15cps
Temperature Range-10-60℃
Diversion Pressure Max≤0.01MPA
Input Voltage220V±10%/50-60Hz
Control ModeXYZ adopts imported servo motors for all three axes
Control ContentPLC control, touch screen+buttons
Liquid Supply MethodPrecision injection pump


The selection of nozzle shape and size for ultrasonic spraying machines requires consideration of multiple factors, including coating properties, spraying requirements, and equipment specifications. Here are some general guiding principles:


1. Coating viscosity: Coatings with lower viscosity typically require smaller nozzle apertures and smaller outlet diameters to ensure uniform and smooth spraying. Higher viscosity coatings may require larger nozzle apertures and outlet diameters for better spraying of the coating.
2. Spraying requirements: The goals and requirements of spraying can also affect the selection of nozzles. For example, if you need to achieve small spray patterns or fine spray control, you may need to choose a nozzle with a smaller nozzle outlet. For applications that require large-scale rapid spraying, it may be necessary to choose a nozzle with a larger nozzle outlet.
3. Particle size of coating: Ultrasonic spraying machines are usually used to disperse coatings into small particles for spraying, so the size of coating particles also affects the selection of nozzles. Smaller paint particles typically require a smaller nozzle aperture.
4. Equipment specifications: The specific specifications and design of the ultrasonic spraying machine may also limit the selection of nozzles. It is necessary to select a matching nozzle based on the technical specifications, operating frequency, amplitude and other parameters of the equipment.
When selecting a nozzle, it is usually necessary to conduct experiments and tests to determine the optimal nozzle shape and size. It can be evaluated and adjusted based on factors such as the fluidity of the coating, spraying effect, and coating thickness. In addition, you can consult the professional technical team of FUNSONIC. FUNSONIC has professional spray application engineers who can provide more specific advice and guidance.

Medical Testing Tube Ultrasonic Coated System 60Khz Penetrator Nozzle Nebulizer

Medical Testing Tube Ultrasonic Coated System 60Khz Penetrator Nozzle Nebulizer

Medical Testing Tube Ultrasonic Coated System 60Khz Penetrator Nozzle Nebulizer























Inquiry Cart 0